Sunam Infrastructure Nirman Pvt. Ltd.
Owner : Vision Energy and Power Ltd.
Installed Capacity : 57.5 MW
Total value : USD $ 25,866,900.87 (Inc. VAT) Civil Works
Major Civil Components of the Project:
No. of Headworks : 2
Headrace Tunnel:
Length : 7250m
Inverted D, Diameter : 3.2m, Height: 3.5-3.8m
Surge Shaft : 48m (Depth)
Penstock:
Length : 1400m
Diameter : 1.2-0.9m
Vertical Shaft : 300m Deep, 2.9m Diameter
Powerhouse Size : 51m x 13m x 27m